您的当前位置:首页正文

冷凝器计算

2023-08-07 来源:星星旅游
冷凝器(tk=40,to=2)换热计算

1.

设计参数: Qk =SRF-120 压缩机制冷剂: R22冷却介质: H2O冷凝温度: tk =进水温度: t1 =出水温度: t2 =水侧污垢系数: γo =2.换热管参数:2.1换热管管内参数:

内径: di =2.2

换热管管外参数:

坯管外径: do = dm =换热管光管段长度: lz = 2×0.05翅片外径: Dw =

翅片根径: Dg =翅片高: h =翅片间隙: S =翅片距: P =

翅片间当量直径: de = 4sh/(2h+s) =传热面积系数: ηc =

单位管长外表面积: Fol = η2c[π(D2w-Dg)/2+πDg·S]/P =2.3

拟取冷凝器参数:

冷凝管根数: nn =过冷管根数: ng = 管程数: Z =

有效管长: l =垂线上的平均管子数:Ncg =

似取冷凝面积(内表面) Fin = nn×π×di×l =3.

水在定性温度下的物性值:

定性温度: tm = (t1+t2)/2 =定压比热: Cp =密度: ρw =动力粘度: μ =普兰德准数: Prw =

第 1 页

W

40℃30℃35

0.000086m2K/W

0.01348m0.01588

m0.1m0.01588m0.01418m0.00085m0.0004m0.00085m0.0006476

m0.80.09232

㎡/m113根0根2程2m9

9.5707992

32.54179J/kg·K994.9kg/m37.62E-04

Pa·S

5.15

导热系数: λ =4.

制冷剂在定性温度下的物性值:定性温度: tmf = tk =导热系数: λf =运动粘度: υf =表面张力: σf =密度: ρf =冷凝潜热: hfg =普兰德准数: Prf =

5.管内水侧给热系数:

5.1冷却水流量: V = Qk/[Cpρw(t2-t1)] =5.2管内水速: ω= 4·Z·V/[(nn+ng)πd2i] =5.3雷诺数: Rew = diωρw/μ =5.4

水侧给热系数:

αi =0.023(λ/di)Re0.80.4wPrw) =

6.管外制冷剂 的给热系数:

6.1毛细作用系数:βc =1-4{σf/[ρf ·(Dg+h)de]}0.5/π=6.2单位面积热负荷:q = Qk/(nn·π·do·l·ηc) =6.3雷诺数 :Ref = 4qdmP/[ρfυf · hfg(2h+S)] =6.4

伽利略准数:G3a = gFol/υ2f =

6.5表面张力作用系数:βσ

= σf (1/0.0001+2/S)/(h·ρf) =

6.6管外给热系数:6.6.1各种系数:①Co = 0.193β 0.5cRe-0.320.31fPrfβσ 0.15G0.1a(0.013/S)2000S =

②不凝气体影响系数;设不凝气体含量为: A = η1 = EXP(-15.6×A) =③

制冷剂含油影响系数:设含油量为:B =η0.82 = [EXP(-8.5×B)] =

④管束效应系数: η-0.253 = Ncg =6.6.2管外给热系数:

αo = η1η2η3C3

2o(λf·

g/υf)1/3 =7.

总传热系数:(按内表面计算)Ki = A[1/αi+di/(dmα-1o)+γo] =

第 2 页

0.6248w/mK40℃0.0772W/mK1.94E-07㎡/s5.80E-04

㎏/m1133㎏/m3166220J/㎏

3.74

0m3/s0m3/h0m/s

00

w/㎡K0.7080087

00

2.051E+119.0337989

#DIV/0!

0.0120.8292779

0.010.93426050.5773503#DIV/0!

W/㎡K

#DIV/0!

8.对数平均温差:Δtm = (t2-t1)/ln[(tk-t1)/(tk-t2)] =9.

传热面积(内表面):Fi' = Qk/(ΔtmKi) =取5%的面积裕量,则 Fi =1.05Fi' =

10.

校核:Fin/Fi =

∵  1≤Fin/Fi ≤1.05 ∴ 计算合格。

11.

水侧阻力计算:

摩擦阻力系数: ξ=0.3164/Rew

水侧阻力: ΔPw = B[R·Z·(l+lz)/di+1.5(Z+1)]ω2·ρw/2 =

12.

接管直径计算:

接管计算水速:ωj =

接管直径:Dj = [4V/(πωj)]0.5 =

第 3 页

7.2134752#DIV/0!#DIV/0!#DIV/0!

#DIV/0!#DIV/0!

20

Pa

m/sm

第 4 页

传热系数修正系数A=1.7

第 5 页

水侧阻力修正系数B=2.5

第 6 页

因篇幅问题不能全部显示,请点此查看更多更全内容